این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
پنجشنبه 23 بهمن 1404
Journal of Periodontology and Implant Dentistry
، جلد ۸، شماره ۲، صفحات ۵۵-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
The effect of mini-implant design on peri-implantitis and pain level after insertion in orthodontic treatment: a prospective clinical study.
چکیده انگلیسی مقاله
Background. Orthodontic mini-implants provide skeletal anchorage for tooth movement. There are two designs of mini-implants, tapered and cylindrical, which exhibit different clinical characteristics, including possible micro-damage to cor-tical bone. Complications such as peri-implantitis and pain after mini-implant placement are common. The aim of this study was to evaluate the effect of mini-implant design on peri-implantitis and post-insertion pain level. Methods. A total of 152 tapered and cylindrical mini-implants were randomly inserted into 76 patients (17 male, 59 fe-male) who were over 16 years of age. Peri-implantitis was assessed using signs of inflammation around mini-implant head. Pain levels of injection, during and immediately after insertion up to one week after implantation, were registered using an 11-point horizontal visual analogue scale (VAS). Data were analyzed using chi-squared and Mann-Whitney U tests. Results. Peri-implantitis was observed in 7% of mini-implants. There was no significant difference between tapered and cylindrical mini-implants in the number of peri-implantitis cases (P > 0.05). Post-insertion pain increased for 6 hours after insertion, and then decreased gradually. None of the patients reported pain a week after mini-implant insertion. There was no significant difference in pain levels of the two groups at all time intervals (P > 0.05). Maximum post-insertion pain (6 hours after implantation: 2.52 ± 2.66) was significantly higher than injection pain (1.38±1.71) (P < 0.001). Conclusion. It was concluded that mini-implant design had no significant effect on peri-implantitis and post-insertion pain level.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
امیر محمدی | amir mohammadi
افسانه ضرغامی | afsaneh zarghami
امیر هومن صدر حقیقی | amir houman sadrhaghighi
نشانی اینترنتی
http://dentistry.tbzmed.ac.ir/jpid/index.php/jpid/article/view/258
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/356/article-356-398576.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Research Article
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات